{"id":15968,"date":"2026-02-08T10:20:17","date_gmt":"2026-02-08T10:20:17","guid":{"rendered":"https:\/\/www.langir.com\/?p=15968"},"modified":"2026-02-28T16:08:58","modified_gmt":"2026-02-28T16:08:58","slug":"what-is-dc-circuit-breaker","status":"publish","type":"news","link":"https:\/\/www.langir.com\/ar\/news\/what-is-dc-circuit-breaker\/","title":{"rendered":"\u0645\u0627 \u0647\u0648 \u0642\u0627\u0637\u0639 \u062f\u0627\u0631\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631: \u0627\u0644\u0623\u0646\u0648\u0627\u0639 \u0648\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0648\u0627\u0644\u062d\u0644\u0648\u0644 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>&nbsp;<\/p>\n<p><!-- \/wp:post-content --><\/p>\n<p><!-- wp:paragraph --><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\">DC circuit breakers<\/a> protect electrical circuits from overloads and short circuits, keeping installations safe and reliable where direct current (DC) is used. This guide walks through common DC breaker types, their typical applications, and the technical differences that set DC protection apart from AC. It\u2019s written for engineers, installers, and system designers who need clear, actionable guidance on selecting the right protection. We also summarize Langir Electric\u2019s solutions and customization options to help you specify the right product for your project.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What is a DC Circuit Breaker and Why is it Essential?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->A DC circuit breaker is a protective device that stops the flow of direct current when it detects an overload or a short circuit. Interrupting the current prevents equipment damage, reduces fire risk, and protects personnel. Because DC does not cross zero like AC, DC breakers require specific designs and operating methods to interrupt current safely and reliably.<\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-16003\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-is-a-DC-Circuit-Breaker-and-Why-is-it-Essential.jpg\" alt=\"What is a DC Circuit Breaker and Why is it Essential\" width=\"759\" height=\"392\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-is-a-DC-Circuit-Breaker-and-Why-is-it-Essential.jpg 759w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-is-a-DC-Circuit-Breaker-and-Why-is-it-Essential-300x155.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-is-a-DC-Circuit-Breaker-and-Why-is-it-Essential-18x9.jpg 18w\" sizes=\"(max-width: 759px) 100vw, 759px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Does a DC Circuit Breaker Protect Electrical Systems?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC breakers monitor current and trip when they detect abnormal conditions. During an overload, they open the circuit to prevent overheating; during a short circuit, they isolate the fault quickly to limit damage. Properly selected breakers prevent cascading failures and keep systems running safely.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph -->Recent studies highlight advanced methods for real-time DC fault interruption.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:quote --><\/p>\n<blockquote class=\"wp-block-quote\">\n<p><strong>Solid-State DC Breaker for Microgrid Fault Protection<\/strong><\/p>\n<p>Demonstrates real-time interruption of DC faults using an active injection circuit. Low-voltage solid-state DC breakers can provide fast, reliable fault protection for isolated DC microgrid clusters.<\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"cite-source\">Low-voltage solid-state DC breaker for fault protection applications in isolated DC microgrid cluster, MSS Danish, 2019<\/span><\/p>\n<\/blockquote>\n<p><!-- \/wp:quote --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Makes DC Circuit Protection Unique Compared to AC?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->The main difference is that DC lacks the natural zero-crossing found in AC. Without that periodic zero, interrupting DC can produce sustained arcing, so DC breakers incorporate specialized arc-management features\u2014magnetic blowout coils, arc chutes, and other measures\u2014to extinguish arcs and safely break the circuit.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph -->This need for effective arc extinction is well documented in arc-extinction research.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:quote --><\/p>\n<blockquote class=\"wp-block-quote\">\n<p><strong>Magnetic Blow-Out for DC Arc Extinction<\/strong><\/p>\n<p>Direct current is harder to interrupt than AC because AC benefits from current-zero points. Magnetic blow-out devices are commonly used to extinguish DC arcs and improve interruption reliability.<\/p>\n<p>Fundamental characteristics of arc extinction by magnetic blow-out at DC voltages (&lt; 500V) II, 2015<\/p>\n<\/blockquote>\n<p><!-- \/wp:quote --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What are the Main Types of DC Circuit Breakers?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC circuit breakers come in several formats to match different voltages, currents, and environments. Choosing the right type depends on system size, fault levels, and installation constraints.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What are DC Miniature Circuit Breakers and Their Uses?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC miniature circuit breakers (MCBs) are compact devices for low-voltage applications, commonly used in residential and light commercial systems. They\u2019re easy to install and reliable for small circuits, but their interruption capability limits them to lower-voltage DC applications where fault currents are manageable.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Do Molded Case Circuit Breakers Differ in DC Applications?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Molded case circuit breakers (MCCBs) are built for higher currents and voltages, making them appropriate for industrial DC systems. MCCBs offer greater breaking capacity and typically include enhanced arc-extinguishing features so they can handle the sustained currents and higher fault levels found in larger DC installations.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>Where are DC Circuit Breakers Commonly Applied in Industry?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC circuit breakers are used across many industries wherever DC power is present. They\u2019re critical for protecting equipment, maintaining uptime, and meeting safety requirements.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-16004\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Where-are-DC-Circuit-Breakers-Commonly-Applied-in-Industry.jpg\" alt=\"Where are DC Circuit Breakers Commonly Applied in Industry\" width=\"553\" height=\"422\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Where-are-DC-Circuit-Breakers-Commonly-Applied-in-Industry.jpg 553w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Where-are-DC-Circuit-Breakers-Commonly-Applied-in-Industry-300x229.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Where-are-DC-Circuit-Breakers-Commonly-Applied-in-Industry-16x12.jpg 16w\" sizes=\"(max-width: 553px) 100vw, 553px\" \/><\/a><\/p>\n<p><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<h3>How Do DC Circuit Breakers Protect Solar Photovoltaic Systems?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->In photovoltaic systems, DC breakers protect solar arrays, combiner boxes, and inverters from overloads and faults. Rapid isolation of faults helps prevent equipment damage and preserves system performance, which is essential for reliable energy production.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Role Do DC Breakers Play in Electric Vehicle Charging Infrastructure?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC breakers are essential in EV fast-charging stations to manage high charging currents and protect chargers and battery systems. Proper DC protection ensures safe operation, reduces downtime, and supports compliant, dependable charging infrastructure.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>How Do AC and DC Circuit Breakers Differ?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Understanding the differences between AC and DC protection helps you choose the right device. The key distinctions are in how each type handles arc interruption and fault transients.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>Why Can&#8217;t AC Circuit Breakers be Used for DC Circuits?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->AC breakers rely on the AC waveform\u2019s zero-crossings to help extinguish arcs. In DC systems, that zero-crossing is absent, so using AC-designed breakers can lead to prolonged arcing and potential equipment damage. For safe, reliable interruption of DC currents, purpose-built DC breakers are required.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph -->The different fault behavior in DC systems means AC protection strategies often aren\u2019t sufficient for DC grids.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:quote --><\/p>\n<blockquote class=\"wp-block-quote\">\n<p><strong>DC Grid Fault Protection System Design<\/strong><\/p>\n<p>Protection schemes designed for AC power systems do not always translate to DC systems, because DC fault transients behave fundamentally differently. Effective DC protection requires purpose-built analysis and design.<\/p>\n<p>&nbsp;<\/p>\n<p><span class=\"cite-source\">Fault analysis and protection system design for DC grids, A Ukil, 2020<\/span><\/p>\n<\/blockquote>\n<p><!-- \/wp:quote --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What are the Key Design Differences Between AC and DC Breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Design differences focus on arc control and interruption methods. DC breakers commonly add magnetic blowouts, longer arc paths, and arc chutes to manage continuous current; AC breakers take advantage of waveform zero-crossings and can use simpler interruption mechanisms.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>How Does Langir\u2019s JB Series Enhance DC Circuit Breaker Performance?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Langir\u2019s JB Series is engineered for dependable DC protection across industrial and commercial applications. The series integrates features aimed at safe interruption, compact installation, and operational reliability.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Features Ensure Safety and Reliability in Langir\u2019s DC Breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Langir DC breakers include bidirectional current protection and a lockable OFF position for secure maintenance isolation. These design choices reduce operational risk and simplify safe servicing in demanding DC environments.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Does Langir\u2019s Customization Service Meet Industrial Needs?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><a href=\"https:\/\/www.langir.com\/contact\/\">Langir Electric<\/a> offers customization options to adapt breakers to specific electrical, mechanical, and regulatory requirements. Tailored solutions help businesses meet unique operational needs and streamline system integration.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>How to Select the Right DC Circuit Breaker for Your Application?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Choosing the right DC breaker requires matching the device to your system\u2019s electrical and environmental conditions so it can protect reliably under real-world faults.<\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-16005\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Select-the-Right-DC-Circuit-Breaker-for-Your-Application.jpg\" alt=\"How to Select the Right DC Circuit Breaker for Your Application\" width=\"486\" height=\"454\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Select-the-Right-DC-Circuit-Breaker-for-Your-Application.jpg 486w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Select-the-Right-DC-Circuit-Breaker-for-Your-Application-300x280.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Select-the-Right-DC-Circuit-Breaker-for-Your-Application-13x12.jpg 13w\" sizes=\"(max-width: 486px) 100vw, 486px\" \/><\/a><\/p>\n<p><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Technical Factors Should Guide DC Circuit Breaker Selection?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Key factors include system voltage and continuous current, peak and fault current levels, breaking capacity, environmental ratings (temperature, humidity, corrosion), and installation constraints. Compliance with applicable standards and coordination with upstream\/downstream protection is also essential.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Do Voltage, Current, and Breaking Capacity Influence Choice?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Voltage and current ratings determine the breaker\u2019s normal operating range, while breaking capacity defines the maximum fault current the breaker can interrupt safely. Select a breaker with ratings and a safety margin that exceed your system\u2019s maximum expected fault current to ensure reliable protection.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What is a DC Circuit Breaker | FAQs<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What are the advantages of using DC circuit breakers in renewable energy systems?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC breakers protect sensitive components like inverters and batteries, isolate faults quickly to prevent equipment damage, and are engineered to handle DC-specific interruption challenges\u2014making them a better match than AC breakers for many renewable installations.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How do environmental conditions affect the performance of DC circuit breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Temperature, humidity, dust, and corrosive atmospheres can reduce a breaker\u2019s reliability and service life. Choose breakers with appropriate IP\/enclosure ratings and materials for the environment, and follow manufacturer guidance for installations in harsh conditions.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What maintenance practices are recommended for DC circuit breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Regular visual inspections, functional trip testing, cleaning and tightening of terminals, and following the manufacturer\u2019s maintenance schedule keep breakers reliable. Address signs of wear, overheating, or corrosion promptly to avoid failures.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>Can DC circuit breakers be used in residential applications?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Yes\u2014DC breakers are commonly used in residential renewable systems such as rooftop solar arrays. Ensure the breaker\u2019s type, voltage, and current ratings match the system and consult a qualified electrician for proper selection and installation.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What are the latest advancements in DC circuit breaker technology?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Advances include solid-state breakers with faster response and enhanced fault detection, and improved arc-extinction techniques such as magnetic blowout and active current injection. These developments increase reliability and reduce maintenance needs in demanding applications.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How do I determine the appropriate breaking capacity for a DC circuit breaker?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Calculate the maximum potential fault current for your system considering source impedance and configuration. Choose a breaker whose breaking capacity exceeds that value with an appropriate safety margin. If needed, consult an electrical engineer or the breaker manufacturer for accurate calculation guidance.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>Conclusion<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC circuit breakers are a critical safety element for renewable-energy systems, EV charging, and other DC-powered installations. Understanding their unique requirements\u2014especially arc management and breaking capacity\u2014helps you specify the right device for reliable operation. For tailored DC protection solutions, explore Langir Electric\u2019s product range and customization services to find the best fit for your project.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n<div class=\"vc-zigzag-wrapper vc-zigzag-align-center\"><div class=\"vc-zigzag-inner\" style=\"width: 100%;min-height: 14px;background: 0 repeat-x url(&#039;data:image\/svg+xml;utf-8,%3C%3Fxml%20version%3D%221.0%22%20encoding%3D%22utf-8%22%3F%3E%3C%21DOCTYPE%20svg%20PUBLIC%20%22-%2F%2FW3C%2F%2FDTD%20SVG%201.1%2F%2FEN%22%20%22http%3A%2F%2Fwww.w3.org%2FGraphics%2FSVG%2F1.1%2FDTD%2Fsvg11.dtd%22%3E%3Csvg%20width%3D%2214px%22%20height%3D%2212px%22%20viewBox%3D%220%200%2018%2015%22%20version%3D%221.1%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%20xmlns%3Axlink%3D%22http%3A%2F%2Fwww.w3.org%2F1999%2Fxlink%22%3E%3Cpolygon%20id%3D%22Combined-Shape%22%20fill%3D%22%23ebebeb%22%20points%3D%228.98762301%200%200%209.12771969%200%2014.519983%209%205.40479869%2018%2014.519983%2018%209.12771969%22%3E%3C%2Fpolygon%3E%3C%2Fsvg%3E&#039;);\"><\/div><\/div><style id=\"wpforms-css-vars-12179\">\n\t\t\t\t#wpforms-12179 {\n\t\t\t\t--wpforms-field-border-color: rgba(0, 0, 0, 0.25);\n--wpforms-field-border-color-spare: rgba(0, 0, 0, 0.25);\n--wpforms-field-text-color: rgba(0, 0, 0, 0.7);\n--wpforms-label-color: rgba(0, 0, 0, 0.85);\n--wpforms-label-sublabel-color: rgba(0, 0, 0, 0.55);\n--wpforms-button-border-radius: 45px;\n--wpforms-button-background-color: #f88404;\n--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n--wpforms-container-shadow-size-box-shadow: none;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-12179\"><form id=\"wpforms-form-12179\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"12179\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/ar\/wp-json\/wp\/v2\/news\/15968?wpforms_form_id=12179\" data-token=\"e71d1359ed1a80b2f0c1de14370d47ba\" data-token-time=\"1776964761\"><div class=\"wpforms-head-container\"><div class=\"wpforms-title\">Get Custom Quote<\/div><div class=\"wpforms-description\">We'll get back to you within 12 hours.<\/div><\/div><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-12179-field_3-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_3\">Your Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_3\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][3]\" placeholder=\"Name\" aria-errormessage=\"wpforms-12179-field_3-error\" required><\/div><div id=\"wpforms-12179-field_1-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_1\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-12179-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" placeholder=\"Email\" spellcheck=\"false\" aria-errormessage=\"wpforms-12179-field_1-error\" required><\/div><div id=\"wpforms-12179-field_6-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"6\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_6\">Country <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_6\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][6]\" placeholder=\"Country\" aria-errormessage=\"wpforms-12179-field_6-error\" required><\/div><div id=\"wpforms-12179-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" placeholder=\"Company\" aria-errormessage=\"wpforms-12179-field_4-error\" required><\/div>\t\t<div id=\"wpforms-12179-field_2-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"2\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-12179-field_2\" >Your Name File<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-12179-field_2\" class=\"wpforms-field-medium\" name=\"wpforms[fields][2]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-12179-field_7-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"7\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_7\">Message <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><textarea id=\"wpforms-12179-field_7\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][7]\" placeholder=\"Message\" aria-errormessage=\"wpforms-12179-field_7-error\" required><\/textarea><\/div><div id=\"wpforms-12179-field_8-container\" class=\"wpforms-field wpforms-field-file-upload\" data-field-id=\"8\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_8\">File Upload (Max 3)<\/label><div\n\t\tclass=\"wpforms-uploader \"\n\t\tdata-field-id=\"8\"\n\t\tdata-form-id=\"12179\"\n\t\tdata-input-name=\"wpforms_12179_8\"\n\t\tdata-extensions=\"jpg,jpeg,jpe,gif,png,bmp,tiff,tif,webp,avif,ico,heic,heif,heics,heifs,asf,asx,wmv,wmx,wm,avi,divx,mov,qt,mpeg,mpg,mpe,mp4,m4v,ogv,webm,mkv,3gp,3gpp,3g2,3gp2,txt,asc,c,cc,h,srt,csv,tsv,ics,rtx,css,vtt,mp3,m4a,m4b,aac,ra,ram,wav,x-wav,ogg,oga,flac,mid,midi,wma,wax,mka,rtf,pdf,class,tar,zip,gz,gzip,rar,7z,psd,xcf,doc,pot,pps,ppt,wri,xla,xls,xlt,xlw,mpp,docx,docm,dotx,dotm,xlsx,xlsm,xlsb,xltx,xltm,xlam,pptx,pptm,ppsx,ppsm,potx,potm,ppam,sldx,sldm,onetoc,onetoc2,onepkg,oxps,xps,odt,odp,ods,odg,odc,odb,odf,wp,wpd,key,numbers,pages\"\n\t\tdata-max-size=\"33554432\"\n\t\tdata-max-file-number=\"3\"\n\t\tdata-post-max-size=\"33554432\"\n\t\tdata-max-parallel-uploads=\"4\"\n\t\tdata-parallel-uploads=\"true\"\n\t\tdata-file-chunk-size=\"2097152\">\n\t<div class=\"dz-message\">\n\t\t<svg  viewBox=\"0 0 640 640\" focusable=\"false\" data-icon=\"inbox\" width=\"50px\" height=\"50px\" fill=\"currentColor\" aria-hidden=\"true\">\n\t\t\t<path d=\"M352 173.3L352 384C352 401.7 337.7 416 320 416C302.3 416 288 401.7 288 384L288 173.3L246.6 214.7C234.1 227.2 213.8 227.2 201.3 214.7C188.8 202.2 188.8 181.9 201.3 169.4L297.3 73.4C309.8 60.9 330.1 60.9 342.6 73.4L438.6 169.4C451.1 181.9 451.1 202.2 438.6 214.7C426.1 227.2 405.8 227.2 393.3 214.7L352 173.3zM320 464C364.2 464 400 428.2 400 384L480 384C515.3 384 544 412.7 544 448L544 480C544 515.3 515.3 544 480 544L160 544C124.7 544 96 515.3 96 480L96 448C96 412.7 124.7 384 160 384L240 384C240 428.2 275.8 464 320 464zM464 488C477.3 488 488 477.3 488 464C488 450.7 477.3 440 464 440C450.7 440 440 450.7 440 464C440 477.3 450.7 488 464 488z\"\/>\n\t\t<\/svg>\n\n\t\t<span class=\"modern-title\">\n\t\t\t\t\t\t\tDrag &amp; Drop Files, \t\t\t\t<span>Choose Files to Upload<\/span>\n\t\t\t\t\t<\/span>\n\n\t\t\t\t\t<span class=\"modern-hint\">You can upload up to 3 files.<\/span>\n\t\t\t<\/div>\n<\/div>\n\n<input\n\t\ttype=\"text\"\n\t\tautocomplete=\"off\"\n\t\treadonly\n\t\tclass=\"dropzone-input\"\n\t\tstyle=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\"\n\t\tid=\"wpforms-12179-field_8\"\n\t\tname=\"wpforms_12179_8\" \t\tvalue=\"\">\n<\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-12179-field_2-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-12179-field_2-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-12179-field_2-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-recaptcha wpforms-is-recaptcha-type-invisible\" ><div class=\"g-recaptcha\" data-sitekey=\"6Lc6I8krAAAAAGhsDV78xMe5sUE34DyWnUTROEYI\" data-size=\"invisible\"><\/div><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"12179\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news\/15968\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-12179\" class=\"wpforms-submit\" data-alt-text=\"Submitting\u2026\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.langir.com\/wp-content\/plugins\/wpforms\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->\n<div class=\"vc-zigzag-wrapper vc-zigzag-align-center\"><div class=\"vc-zigzag-inner\" style=\"width: 100%;min-height: 14px;background: 0 repeat-x url(&#039;data:image\/svg+xml;utf-8,%3C%3Fxml%20version%3D%221.0%22%20encoding%3D%22utf-8%22%3F%3E%3C%21DOCTYPE%20svg%20PUBLIC%20%22-%2F%2FW3C%2F%2FDTD%20SVG%201.1%2F%2FEN%22%20%22http%3A%2F%2Fwww.w3.org%2FGraphics%2FSVG%2F1.1%2FDTD%2Fsvg11.dtd%22%3E%3Csvg%20width%3D%2214px%22%20height%3D%2212px%22%20viewBox%3D%220%200%2018%2015%22%20version%3D%221.1%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%20xmlns%3Axlink%3D%22http%3A%2F%2Fwww.w3.org%2F1999%2Fxlink%22%3E%3Cpolygon%20id%3D%22Combined-Shape%22%20fill%3D%22%23ebebeb%22%20points%3D%228.98762301%200%200%209.12771969%200%2014.519983%209%205.40479869%2018%2014.519983%2018%209.12771969%22%3E%3C%2Fpolygon%3E%3C%2Fsvg%3E&#039;);\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>\u0647\u0644 \u062a\u0633\u0627\u0621\u0644\u062a \u064a\u0648\u0645\u0627\u064b \u0645\u0627 \u0647\u0648 \u0642\u0627\u0637\u0639 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u061f \u062f\u0639\u0646\u0627 \u0646\u0641\u0635\u0644\u0647\u0627 \u0628\u0637\u0631\u064a\u0642\u0629 \u0645\u0645\u062a\u0639\u0629. \u062a\u0639\u0644\u0645 \u0623\u0633\u0627\u0633\u064a\u0627\u062a \u0627\u0644\u0633\u0644\u0627\u0645\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0648\u062d\u0627\u0641\u0638 \u0639\u0644\u0649 \u0633\u0644\u0627\u0645\u0629 \u0645\u0646\u0632\u0644\u0643!<\/p>","protected":false},"author":3,"featured_media":16002,"menu_order":16,"comment_status":"closed","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"news_category":[6],"class_list":["post-15968","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-news","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news\/15968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/comments?post=15968"}],"version-history":[{"count":2,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news\/15968\/revisions"}],"predecessor-version":[{"id":16006,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news\/15968\/revisions\/16006"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/media\/16002"}],"wp:attachment":[{"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/media?parent=15968"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.langir.com\/ar\/wp-json\/wp\/v2\/news_category?post=15968"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}