{"id":15966,"date":"2026-02-12T10:14:44","date_gmt":"2026-02-12T10:14:44","guid":{"rendered":"https:\/\/www.langir.com\/?p=15966"},"modified":"2026-02-28T16:59:34","modified_gmt":"2026-02-28T16:59:34","slug":"calculate-dc-circuit-breaker-ratings","status":"publish","type":"news","link":"https:\/\/www.langir.com\/ru\/news\/calculate-dc-circuit-breaker-ratings\/","title":{"rendered":"\u041a\u0430\u043a \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044b \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: \u041f\u043e\u043b\u043d\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043e\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u0438\u044e \u0440\u0430\u0437\u043c\u0435\u0440\u043e\u0432 \u0438 \u0432\u044b\u0431\u043e\u0440\u0443"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>&nbsp;<\/p>\n<p><!-- \/wp:post-content --><\/p>\n<p><!-- wp:paragraph -->Sizing the right circuit breaker for a DC circuit is essential to protect equipment and keep systems running reliably. This guide walks you through the principles that matter for DC breaker selection: DC fundamentals, the parameters that drive ratings, and clear, step\u2011by\u2011step calculation methods. Many installers and designers struggle with choosing the correct breaker, which can cause nuisance trips or, worse, equipment damage. Follow this guide to determine accurate breaker ratings for common use cases \u2014 from solar arrays and battery banks to demanding industrial loads \u2014 and learn how Langir Electric\u2019s JB Series meets those needs.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What Are the Fundamentals of DC Circuits and Circuit Breakers?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Knowing how DC circuits behave is the foundation of correct breaker sizing. Direct current flows in a single direction, which changes how faults and interruptions behave compared with AC circuits. Circuit breakers are protective devices that stop excessive current during overloads or shorts to prevent component damage, fires, and unsafe conditions.<\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-16013\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-Are-the-Fundamentals-of-DC-Circuits-and-Circuit-Breakers.jpg\" alt=\"What Are the Fundamentals of DC Circuits and Circuit Breakers\" width=\"759\" height=\"392\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-Are-the-Fundamentals-of-DC-Circuits-and-Circuit-Breakers.jpg 759w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-Are-the-Fundamentals-of-DC-Circuits-and-Circuit-Breakers-300x155.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/What-Are-the-Fundamentals-of-DC-Circuits-and-Circuit-Breakers-18x9.jpg 18w\" sizes=\"(max-width: 759px) 100vw, 759px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Is a DC Circuit Breaker and How Does It Differ from AC Breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\">A DC circuit breaker<\/a> is engineered for the continuous, one\u2011direction current characteristic of DC systems. Because DC lacks the zero\u2011crossing that helps AC breakers extinguish arcs, DC breakers use stronger arc\u2011quenching and dedicated trip mechanisms \u2014 magnetic, electronic, or hybrid designs \u2014 to interrupt current safely. Typical applications include renewable energy systems, battery storage, and electric vehicles where reliable DC protection is critical.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>Which Basic Electrical Principles Affect DC Circuit Breaker Sizing?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Several core electrical principles inform breaker sizing. Ohm\u2019s Law (V = I \u00d7 R) lets you relate voltage, current and resistance when determining expected currents. Power relationships (P = V \u00d7 I) and the system\u2019s operating voltage also affect current levels and component selection. Applying these fundamentals ensures the selected breaker will carry normal load without nuisance trips while still clearing faults effectively.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What Key Parameters Influence DC Circuit Breaker Rating Calculations?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Breaker ratings rely on a set of measurable parameters: the expected load current, the system voltage, the maximum possible short\u2011circuit current, and the breaker\u2019s breaking capacity. Each parameter contributes to safe, reliable operation and must be verified during design and procurement.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Do Load Current and Continuous Load Factor Determine Breaker Size?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Load current is the current the circuit will carry during regular operation. Because some loads run continuously, designers apply a continuous load factor \u2014 a safety multiplier \u2014 to avoid nuisance trips and overheating. Multiply the expected load current by the continuous load factor to establish the minimum breaker rating that will reliably carry the load.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>Why Are Voltage Rating, Short Circuit Current, and Breaking Capacity Critical?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->The voltage rating shows the maximum system voltage the breaker can safely interrupt. Short\u2011circuit current is the highest current that could flow during a fault, and breaking capacity (or interrupting rating) is the maximum fault current the breaker can safely interrupt. Selecting a breaker with an appropriate voltage rating and breaking capacity is essential to avoid equipment damage or failure during fault conditions.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>How to Calculate DC Circuit Breaker Size: Step-by-Step Formulas and Examples<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Use a straightforward, methodical approach when calculating breaker size. The following steps and examples make the process repeatable across applications.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Is the General Formula for DC Circuit Breaker Sizing?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->The general sizing rule is:<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph -->This gives the minimum breaker rating to carry the load under normal operating conditions. Typical continuous load factors range from 1.25 to 1.5 depending on the application and code requirements.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How to Calculate Breaker Rating for Solar PV, Battery Banks, and Industrial Loads?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Specific applications call for small adjustments to the basic formula. For example, for a solar PV string you should size the breaker for the panel&#8217;s maximum output current plus a safety margin:<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:paragraph -->This accounts for peak production and prevents nuisance trips during maximum insolation. For battery banks, size the breaker to handle maximum continuous and peak discharge currents. For industrial loads, include startup and inrush currents in your load current estimate before applying the continuous load factor.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>Which Selection Criteria Should Guide Choosing the Right DC Circuit Breaker?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Choose a breaker based on the application\u2019s electrical and environmental demands. Key criteria include the breaker\u2019s trip characteristics, pole configuration, environmental ratings, and compliance with relevant codes and standards.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-16014\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Which-Selection-Criteria-Should-Guide-Choosing-the-Right-DC-Circuit-Breaker.jpg\" alt=\"Which Selection Criteria Should Guide Choosing the Right DC Circuit Breaker\" width=\"526\" height=\"361\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Which-Selection-Criteria-Should-Guide-Choosing-the-Right-DC-Circuit-Breaker.jpg 526w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Which-Selection-Criteria-Should-Guide-Choosing-the-Right-DC-Circuit-Breaker-300x206.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/Which-Selection-Criteria-Should-Guide-Choosing-the-Right-DC-Circuit-Breaker-18x12.jpg 18w\" sizes=\"(max-width: 526px) 100vw, 526px\" \/><\/a><\/p>\n<p><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<h3>How Do Trip Curves, Number of Poles, and Environmental Factors Affect Selection?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Trip curves describe the time\u2011current response of a breaker and help you match protection to the load\u2019s normal and fault behavior. The number of poles depends on the circuit layout \u2014 single\u2011pole for many DC systems, multi\u2011pole for multi\u2011conductor or multi\u2011string setups. Environmental conditions such as ambient temperature, humidity, dust, or corrosive atmospheres affect thermal performance and long\u2011term reliability, so select breakers rated for the environment where they\u2019ll be installed.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Are the NEC and International Standards for DC Circuit Breaker Compliance?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->National and international codes \u2014 including the NEC and IEC standards \u2014 set minimum safety and installation requirements. These standards guide correct breaker sizing, installation methods, and labeling so systems meet legal and safety expectations. Always verify local code requirements and applicable standards during design and procurement.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What Are the Features and Benefits of Langir JB Series DC Circuit Breakers?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Langir\u2019s JB Series is built to deliver dependable protection and flexible installation across DC applications. The series combines reliable trip mechanisms, compact form factors, and ratings suitable for renewable, storage, and industrial systems.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Does the JB Series Provide Reliable Protection and Bidirectional Current Flow?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->JB Series breakers include robust overload and short\u2011circuit protection and are designed to support bidirectional current flow \u2014 a key requirement for systems like solar + storage where current can reverse during charging and discharging. That bidirectional capability, together with consistent trip performance, makes JB Series ideal for modern DC systems.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What Customization Options Does Langir Offer for DC Circuit Breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph --><a href=\"https:\/\/www.langir.com\/contact\/\">Langir Electric<\/a> provides customization to match specific system needs. Options include tailored voltage ratings, higher breaking capacities, and modified trip characteristics so the breaker aligns with unique system requirements and operational profiles. Custom configurations are especially useful for specialized industrial or large renewable projects.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>What Common Questions Arise About DC Circuit Breaker Sizing and Selection?<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Below are concise answers to frequent design and selection questions that come up during system planning and installation.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Do You Calculate DC Circuit Breaker Size Using the 125 Percent Rule?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->The 125 percent rule is a common guideline for continuous loads: multiply the continuous load current by 1.25 to determine the breaker rating. This built\u2011in margin helps prevent nuisance tripping and allows safe, continuous operation.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How Do NEC Requirements Impact DC Circuit Breaker Selection?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->NEC rules define minimum sizing practices, installation methods, and labeling for safety and code compliance. NEC requirements often dictate the continuous load multipliers, wiring limits, and protective device placement; follow them to ensure installations are safe and meet inspection criteria.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:table --><\/p>\n<figure class=\"wp-block-table meta-block-tabel\">\n<table style=\"border: 1px solid grey; border-collapse: collapse;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid grey; border-collapse: collapse;\">Parameter<\/th>\n<th style=\"border: 1px solid grey; border-collapse: collapse;\">Description<\/th>\n<th style=\"border: 1px solid grey; border-collapse: collapse;\">Importance<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Load Current<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Expected operating current the circuit will carry<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Determines the base breaker size<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Voltage Rating<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Maximum system voltage the breaker can interrupt safely<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Ensures proper insulation and safe interruption<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Short Circuit Current<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Maximum fault current that could flow in the circuit<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Used to verify breaker interrupting ability<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Breaking Capacity<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Maximum current the breaker can interrupt without damage<\/td>\n<td style=\"border: 1px solid grey; border-collapse: collapse;\">Protects the breaker and the system during faults<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:table --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>How to Calculate DC Circuit Breaker Ratings | FAQs<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<p><a href=\"https:\/\/www.langir.com\/dc-circuit-breaker\/\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-16015\" src=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Calculate-DC-Circuit-Breaker-Ratings-FAQs.jpg\" alt=\"How to Calculate DC Circuit Breaker Ratings FAQs\" width=\"733\" height=\"489\" srcset=\"https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Calculate-DC-Circuit-Breaker-Ratings-FAQs.jpg 733w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Calculate-DC-Circuit-Breaker-Ratings-FAQs-300x200.jpg 300w, https:\/\/www.langir.com\/wp-content\/uploads\/2026\/02\/How-to-Calculate-DC-Circuit-Breaker-Ratings-FAQs-18x12.jpg 18w\" sizes=\"(max-width: 733px) 100vw, 733px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a class=\"pum-trigger\" href=\"http:\/#popmake-11886\"><u>Get a quote for custom DC circuit breakers from Langir<\/u><\/a><\/p>\n<h3>What is the importance of selecting the right continuous load factor?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->The continuous load factor gives a safety margin for sustained operation. Using a multiplier\u2014commonly 1.25 to 1.5\u2014accounts for sustained loads and minor fluctuations, reducing nuisance trips and preventing overheating. Choosing the correct factor improves reliability and protects both the breaker and connected equipment.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How can environmental conditions affect DC circuit breaker performance?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Ambient conditions influence breaker thermal performance and long\u2011term reliability. High temperature raises internal temperatures and can lower allowable current ratings; moisture and corrosives can harm contacts and housings. Always select breakers with environmental ratings and derating guidance appropriate for the installation.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What are the common applications for DC circuit breakers?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC breakers are used widely in solar PV systems, battery energy storage, electric vehicles, telecom power systems, and certain industrial machinery. Wherever DC power is present, appropriate protection is required to safeguard equipment and personnel.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>How do you determine the breaking capacity needed for a DC circuit breaker?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Calculate the maximum prospective short\u2011circuit current at the breaker location based on system impedance and fault scenarios. Select a breaker whose breaking capacity exceeds that calculated value so it can interrupt the fault without sustaining damage.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>What role do trip curves play in circuit breaker selection?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Trip curves show how long the breaker takes to open at various overcurrent levels. Matching the trip curve to the load profile avoids nuisance trips from inrush currents while ensuring fast clearing of dangerous faults. Choose a curve that balances protection and operational tolerance for your specific load.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":3} --><\/p>\n<h3>Can DC circuit breakers be used in AC applications?<\/h3>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->DC breakers are designed specifically for direct current and are not interchangeable with AC breakers in most cases. AC breakers rely on current zero\u2011crossing for arc extinction; using a DC breaker in AC service\u2014or vice versa\u2014can result in inadequate protection. Always use the type specified for the circuit.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n<p><!-- wp:heading {\"level\":2} --><\/p>\n<h2>Conclusion<\/h2>\n<p><!-- \/wp:heading --><\/p>\n<p><!-- wp:paragraph -->Correctly calculating DC breaker ratings protects equipment, improves uptime, and keeps installations safe. By focusing on load current, voltage, short\u2011circuit currents, and breaking capacity \u2014 and by following applicable codes \u2014 you can select breakers that perform reliably. For tailored solutions, explore Langir\u2019s resources or contact our team to match JB Series breakers to your system requirements. Start optimizing your DC systems for safer, more efficient operation today.<\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n<div class=\"vc-zigzag-wrapper vc-zigzag-align-center\"><div class=\"vc-zigzag-inner\" style=\"width: 100%;min-height: 14px;background: 0 repeat-x url(&#039;data:image\/svg+xml;utf-8,%3C%3Fxml%20version%3D%221.0%22%20encoding%3D%22utf-8%22%3F%3E%3C%21DOCTYPE%20svg%20PUBLIC%20%22-%2F%2FW3C%2F%2FDTD%20SVG%201.1%2F%2FEN%22%20%22http%3A%2F%2Fwww.w3.org%2FGraphics%2FSVG%2F1.1%2FDTD%2Fsvg11.dtd%22%3E%3Csvg%20width%3D%2214px%22%20height%3D%2212px%22%20viewBox%3D%220%200%2018%2015%22%20version%3D%221.1%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%20xmlns%3Axlink%3D%22http%3A%2F%2Fwww.w3.org%2F1999%2Fxlink%22%3E%3Cpolygon%20id%3D%22Combined-Shape%22%20fill%3D%22%23ebebeb%22%20points%3D%228.98762301%200%200%209.12771969%200%2014.519983%209%205.40479869%2018%2014.519983%2018%209.12771969%22%3E%3C%2Fpolygon%3E%3C%2Fsvg%3E&#039;);\"><\/div><\/div><style id=\"wpforms-css-vars-12179\">\n\t\t\t\t#wpforms-12179 {\n\t\t\t\t--wpforms-field-border-color: rgba(0, 0, 0, 0.25);\n--wpforms-field-border-color-spare: rgba(0, 0, 0, 0.25);\n--wpforms-field-text-color: rgba(0, 0, 0, 0.7);\n--wpforms-label-color: rgba(0, 0, 0, 0.85);\n--wpforms-label-sublabel-color: rgba(0, 0, 0, 0.55);\n--wpforms-button-border-radius: 45px;\n--wpforms-button-background-color: #f88404;\n--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n--wpforms-container-shadow-size-box-shadow: none;\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-12179\"><form id=\"wpforms-form-12179\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"12179\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/ru\/wp-json\/wp\/v2\/news\/15966?wpforms_form_id=12179\" data-token=\"383b766d11677679b463097300c7c33a\" data-token-time=\"1776231571\"><div class=\"wpforms-head-container\"><div class=\"wpforms-title\">Get Custom Quote<\/div><div class=\"wpforms-description\">We'll get back to you within 12 hours.<\/div><\/div><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-12179-field_3-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_3\">Your Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_3\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][3]\" placeholder=\"Name\" aria-errormessage=\"wpforms-12179-field_3-error\" required><\/div><div id=\"wpforms-12179-field_1-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"1\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_1\">Email <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-12179-field_1\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][1]\" placeholder=\"Email\" spellcheck=\"false\" aria-errormessage=\"wpforms-12179-field_1-error\" required><\/div><div id=\"wpforms-12179-field_6-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"6\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_6\">Country <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_6\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][6]\" placeholder=\"Country\" aria-errormessage=\"wpforms-12179-field_6-error\" required><\/div><div id=\"wpforms-12179-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_4\">Company <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-12179-field_4\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][4]\" placeholder=\"Company\" aria-errormessage=\"wpforms-12179-field_4-error\" required><\/div><div id=\"wpforms-12179-field_7-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"7\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_7\">Message <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><textarea id=\"wpforms-12179-field_7\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][7]\" placeholder=\"Message\" aria-errormessage=\"wpforms-12179-field_7-error\" required><\/textarea><\/div>\t\t<div id=\"wpforms-12179-field_2-container\"\n\t\t\tclass=\"wpforms-field wpforms-field-text\"\n\t\t\tdata-field-type=\"text\"\n\t\t\tdata-field-id=\"2\"\n\t\t\t>\n\t\t\t<label class=\"wpforms-field-label\" for=\"wpforms-12179-field_2\" >Company Your Message<\/label>\n\t\t\t<input type=\"text\" id=\"wpforms-12179-field_2\" class=\"wpforms-field-medium\" name=\"wpforms[fields][2]\" >\n\t\t<\/div>\n\t\t<div id=\"wpforms-12179-field_8-container\" class=\"wpforms-field wpforms-field-file-upload\" data-field-id=\"8\"><label class=\"wpforms-field-label\" for=\"wpforms-12179-field_8\">File Upload (Max 3)<\/label><div\n\t\tclass=\"wpforms-uploader \"\n\t\tdata-field-id=\"8\"\n\t\tdata-form-id=\"12179\"\n\t\tdata-input-name=\"wpforms_12179_8\"\n\t\tdata-extensions=\"jpg,jpeg,jpe,gif,png,bmp,tiff,tif,webp,avif,ico,heic,heif,heics,heifs,asf,asx,wmv,wmx,wm,avi,divx,mov,qt,mpeg,mpg,mpe,mp4,m4v,ogv,webm,mkv,3gp,3gpp,3g2,3gp2,txt,asc,c,cc,h,srt,csv,tsv,ics,rtx,css,vtt,mp3,m4a,m4b,aac,ra,ram,wav,x-wav,ogg,oga,flac,mid,midi,wma,wax,mka,rtf,pdf,class,tar,zip,gz,gzip,rar,7z,psd,xcf,doc,pot,pps,ppt,wri,xla,xls,xlt,xlw,mpp,docx,docm,dotx,dotm,xlsx,xlsm,xlsb,xltx,xltm,xlam,pptx,pptm,ppsx,ppsm,potx,potm,ppam,sldx,sldm,onetoc,onetoc2,onepkg,oxps,xps,odt,odp,ods,odg,odc,odb,odf,wp,wpd,key,numbers,pages\"\n\t\tdata-max-size=\"33554432\"\n\t\tdata-max-file-number=\"3\"\n\t\tdata-post-max-size=\"33554432\"\n\t\tdata-max-parallel-uploads=\"4\"\n\t\tdata-parallel-uploads=\"true\"\n\t\tdata-file-chunk-size=\"2097152\">\n\t<div class=\"dz-message\">\n\t\t<svg  viewBox=\"0 0 640 640\" focusable=\"false\" data-icon=\"inbox\" width=\"50px\" height=\"50px\" fill=\"currentColor\" aria-hidden=\"true\">\n\t\t\t<path d=\"M352 173.3L352 384C352 401.7 337.7 416 320 416C302.3 416 288 401.7 288 384L288 173.3L246.6 214.7C234.1 227.2 213.8 227.2 201.3 214.7C188.8 202.2 188.8 181.9 201.3 169.4L297.3 73.4C309.8 60.9 330.1 60.9 342.6 73.4L438.6 169.4C451.1 181.9 451.1 202.2 438.6 214.7C426.1 227.2 405.8 227.2 393.3 214.7L352 173.3zM320 464C364.2 464 400 428.2 400 384L480 384C515.3 384 544 412.7 544 448L544 480C544 515.3 515.3 544 480 544L160 544C124.7 544 96 515.3 96 480L96 448C96 412.7 124.7 384 160 384L240 384C240 428.2 275.8 464 320 464zM464 488C477.3 488 488 477.3 488 464C488 450.7 477.3 440 464 440C450.7 440 440 450.7 440 464C440 477.3 450.7 488 464 488z\"\/>\n\t\t<\/svg>\n\n\t\t<span class=\"modern-title\">\n\t\t\t\t\t\t\tDrag &amp; Drop Files, \t\t\t\t<span>Choose Files to Upload<\/span>\n\t\t\t\t\t<\/span>\n\n\t\t\t\t\t<span class=\"modern-hint\">You can upload up to 3 files.<\/span>\n\t\t\t<\/div>\n<\/div>\n\n<input\n\t\ttype=\"text\"\n\t\tautocomplete=\"off\"\n\t\treadonly\n\t\tclass=\"dropzone-input\"\n\t\tstyle=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\"\n\t\tid=\"wpforms-12179-field_8\"\n\t\tname=\"wpforms_12179_8\" \t\tvalue=\"\">\n<\/div><script>\n\t\t\t\t( function() {\n\t\t\t\t\tconst style = document.createElement( 'style' );\n\t\t\t\t\tstyle.appendChild( document.createTextNode( '#wpforms-12179-field_2-container { position: absolute !important; overflow: hidden !important; display: inline !important; height: 1px !important; width: 1px !important; z-index: -1000 !important; padding: 0 !important; } #wpforms-12179-field_2-container input { visibility: hidden; } #wpforms-conversational-form-page #wpforms-12179-field_2-container label { counter-increment: none; }' ) );\n\t\t\t\t\tdocument.head.appendChild( style );\n\t\t\t\t\tdocument.currentScript?.remove();\n\t\t\t\t} )();\n\t\t\t<\/script><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-recaptcha wpforms-is-recaptcha-type-invisible\" ><div class=\"g-recaptcha\" data-sitekey=\"6Lc6I8krAAAAAGhsDV78xMe5sUE34DyWnUTROEYI\" data-size=\"invisible\"><\/div><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"12179\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news\/15966\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-12179\" class=\"wpforms-submit\" data-alt-text=\"Submitting\u2026\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Submit<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.langir.com\/wp-content\/plugins\/wpforms\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><\/form><\/div>  <!-- .wpforms-container -->\n<div class=\"vc-zigzag-wrapper vc-zigzag-align-center\"><div class=\"vc-zigzag-inner\" style=\"width: 100%;min-height: 14px;background: 0 repeat-x url(&#039;data:image\/svg+xml;utf-8,%3C%3Fxml%20version%3D%221.0%22%20encoding%3D%22utf-8%22%3F%3E%3C%21DOCTYPE%20svg%20PUBLIC%20%22-%2F%2FW3C%2F%2FDTD%20SVG%201.1%2F%2FEN%22%20%22http%3A%2F%2Fwww.w3.org%2FGraphics%2FSVG%2F1.1%2FDTD%2Fsvg11.dtd%22%3E%3Csvg%20width%3D%2214px%22%20height%3D%2212px%22%20viewBox%3D%220%200%2018%2015%22%20version%3D%221.1%22%20xmlns%3D%22http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%22%20xmlns%3Axlink%3D%22http%3A%2F%2Fwww.w3.org%2F1999%2Fxlink%22%3E%3Cpolygon%20id%3D%22Combined-Shape%22%20fill%3D%22%23ebebeb%22%20points%3D%228.98762301%200%200%209.12771969%200%2014.519983%209%205.40479869%2018%2014.519983%2018%209.12771969%22%3E%3C%2Fpolygon%3E%3C%2Fsvg%3E&#039;);\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>\u0423\u0437\u043d\u0430\u0439\u0442\u0435, \u043a\u0430\u043a \u0440\u0430\u0441\u0441\u0447\u0438\u0442\u0430\u0442\u044c \u043d\u043e\u043c\u0438\u043d\u0430\u043b\u044b \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0445 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0435\u0439 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 \u0431\u0435\u0437 \u043e\u0441\u043e\u0431\u044b\u0445 \u0443\u0441\u0438\u043b\u0438\u0439! \u041f\u043e\u043b\u0443\u0447\u0438\u0442\u0435 \u0441\u043e\u0432\u0435\u0442\u044b \u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438 \u044d\u043a\u0441\u043f\u0435\u0440\u0442\u043e\u0432, \u043a\u043e\u0442\u043e\u0440\u044b\u0435 \u0441\u0434\u0435\u043b\u0430\u044e\u0442 \u044d\u0442\u043e\u0442 \u043f\u0440\u043e\u0446\u0435\u0441\u0441 \u0443\u0432\u043b\u0435\u043a\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u043c \u0438 \u043f\u043e\u043d\u044f\u0442\u043d\u044b\u043c \u0434\u043b\u044f \u0432\u0441\u0435\u0445.<\/p>","protected":false},"author":3,"featured_media":16012,"menu_order":14,"comment_status":"closed","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"news_category":[6],"class_list":["post-15966","news","type-news","status-publish","format-standard","has-post-thumbnail","hentry","news_category-news","entry"],"acf":[],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news\/15966","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/types\/news"}],"author":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/comments?post=15966"}],"version-history":[{"count":2,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news\/15966\/revisions"}],"predecessor-version":[{"id":16016,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news\/15966\/revisions\/16016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/media\/16012"}],"wp:attachment":[{"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/media?parent=15966"}],"wp:term":[{"taxonomy":"news_category","embeddable":true,"href":"https:\/\/www.langir.com\/ru\/wp-json\/wp\/v2\/news_category?post=15966"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}